irot Kalibrat

Calibration register template Calibration tracking in Excel – the template, and where it ends.

Most calibration systems start as a spreadsheet. That is fine – if it has the right columns and someone looks at it every week. Here is a free template with those columns, and an honest list of what a spreadsheet cannot do.

Last updated: November 13, 2026 · Reviewed by irot

  • Free for up to 20 devices
  • No payment details
  • Interface in English and German
Import
Importing a spreadsheet into Kalibrat

The free template

Download calibration register template (.xlsx) CSV

Opens in Excel, LibreOffice and Google Sheets. Six example rows show how the columns are filled – a caliper, a micrometer, a torque wrench, a pressure gauge, a gauge block set and a blocked height gauge. Replace or delete them. One row per device, with these columns:

Asset ID
Your own number, unique, also on the label.
Description
What it is: “Digital caliper 150 mm”.
Manufacturer, Model, Serial number
To identify the exact device in a certificate.
Range, Tolerance
What it may be used for – the basis of every conformity decision.
Location, Department, Responsible person
Where it is and who answers for it.
Interval (months)
Your decision, documented.
Last calibration, Next due
Dates. In the examples “next due” is already calculated; in your own rows use =EDATE(L2,K2) instead of typing it – or the due date calculator.
Calibrated by, Certificate no.
In-house or which lab; the certificate you can show.
Status, Notes
In use, blocked, out of service – and why.

The column names are the ones Kalibrat recognises when you import, so this file is also the shortest way into the software later.

Four formulas that make the sheet work

A calibration log only helps if it tells you what is coming. These four lines turn the template from a list into a tool. Column letters are those of the template: K is the interval, L the last calibration, M the next due date, P the status.

  1. Next due date: =EDATE(L2,K2) in M2, copied down. Never type a due date by hand – a typed date does not move when the calibration date changes.
  2. Overdue in red: conditional formatting on column M with the formula =AND($M2<>"",$M2<TODAY()).
  3. Due within 30 days in amber: a second rule, =AND($M2>=TODAY(),$M2<=TODAY()+30).
  4. A count at the top: =COUNTIFS(M:M,"<"&TODAY(),P:P,"In use") shows how many devices in use are overdue – the number an auditor looks for first.

With European regional settings, Excel separates arguments with a semicolon instead of a comma: =EDATE(L2;K2).

Keep the history, not just the latest date

The register sheet shows the current state of each device. The evidence lives somewhere else: add a second sheet, “History”, with one row per calibration – asset ID, date, result, who calibrated, certificate number, and what was done if the device was out of tolerance. Never delete a row there; if an entry was wrong, add a correcting row that says so. Keep the certificates as PDFs in one folder and name each file after the asset ID and the date, for example G-0003_2025-12-04.pdf, so anyone can find the certificate for a line in seconds.

A weekly routine that keeps it honest

  • Monday: filter for amber and red, send what is due to the lab or the in-house calibration bench, and note the date it left.
  • When a device comes back: enter the date and the result in the History sheet first, then update the register row.
  • When a device fails: mark it as blocked, take it out of use, and write down which products it measured since its last good calibration – ISO 9001 expects you to assess them.
  • Once a month: check that every device on the shop floor appears in the sheet, and that every row in the sheet still exists on the shop floor.

For the yearly workload behind this routine see the calibration schedule guide; for typical starting values, calibration intervals.

Where a spreadsheet stops being enough

  • Nobody gets reminded. A conditional format turns a cell red; it does not send an e-mail to the person who has the gauge in their drawer.
  • History disappears. When the new date is typed over the old one, the evidence of the previous calibration is gone – and that is exactly what an auditor asks for.
  • Several people, several versions. A copy on the desktop, one in the e-mail, one on the share. Which one is the register?
  • No status on the device. The person at the machine cannot see whether the micrometer in their hand is still valid.
  • Out-of-tolerance findings have no trail. Which parts were measured with the device since its last good calibration? The spreadsheet does not know.

Moving on without starting over

Kalibrat imports this template – or the list you already have – in a few minutes: upload, check the column mapping, look at the preview, import. Up to 20 devices it stays free. Still deciding? Read the comparison of Excel and calibration software.

FAQ

Frequently asked questions

Is there a free calibration tracking template?

Yes, the template on this page is free to download and use, as an Excel file (.xlsx) or as CSV. It opens in Excel, LibreOffice and Google Sheets.

How do I calculate the next calibration date in Excel?

Use EDATE with the last calibration date and the interval in months. In this template that is =EDATE(L2,K2) – or =EDATE(L2;K2), depending on your regional settings. Format the cell as a date.

Is a spreadsheet acceptable for ISO 9001?

It can be, if it is complete, controlled and kept up to date, and if the history of each calibration is retained. In practice the history and the reminders are where spreadsheets fail.

Import your spreadsheet – free up to 20 devices

Free for up to 20 devices, for as long as you like, with no payment details. Set up in three minutes – e-mail, your company, done. Your spreadsheet comes along.

Start free See pricing